Central air conditioners: ratings, sizing and what they cost to run

A central air conditioner cools through ducts. Its rating tells you how much cooling each unit of electricity buys, and the ductwork around it decides how much of that you get.

By VoltHearth Editorial Team Updated 6 min read

Rating to compare
SEER2
Federal standards began
Jan. 1, 2023
Regions with minimums
Three regions
Federal credit (25C)
Ended Dec. 31, 2025
Illustration: an outdoor condenser unit beside a house with ducts in the attic

At a glance

A central air conditioner moves heat out of the house with a refrigerant loop and delivers cool air through ducts. Its seasonal rating is SEER2: the heat removed over a cooling season divided by the electricity used. Federal minimums have varied by region since January 1, 2023. A higher SEER2 lowers the kilowatt-hours for the same cooling, but leaky ducts and a wrong-sized unit can cancel the gain. The federal credit ended for 2026 installs.

What a central air conditioner does

A central air conditioner has an outdoor unit with a compressor and coil, and an indoor coil that sits in the air handler or on top of a furnace. Refrigerant carries heat from indoor air to the outdoor unit. ENERGY STAR notes that the system needs a blower motor, usually part of the furnace, to push air through the duct system. That link matters when you replace one half: the blower, the ducts and the coil are all part of the cooling you get.

A heat pump uses the same equipment and reverses the flow to heat as well. If you are replacing an air conditioner and a furnace in the same house, compare a heat pump and a gas furnace with a matching air conditioner before you decide.

How it is rated

SEER2

The Department of Energy defines SEER2 as the total heat removed from the conditioned space during the cooling season, divided by the total electrical energy the unit uses over that season. Higher means more cooling per kWh. It replaced the older SEER after DOE changed the test to better reflect real installations.

EER2

EER2 is a companion rating measured at a single test condition rather than averaged over a season. DOE sets EER2 floors for the Southwest, on top of its SEER2 minimum.

DOE says SEER2, HSPF2 and EER2 are similar to the older ratings but not directly comparable, so you cannot subtract a fixed amount from an old SEER number to get a SEER2 number. Compare SEER2 with SEER2.

Federal minimum SEER2 for split-system air conditioners installed from Jan. 1, 2023
RegionUnder 45,000 Btu/hr45,000 Btu/hr or more
North13.413.4
Southeast14.313.8
Southwest14.3, plus an EER2 floor13.8, plus an EER2 floor

The table follows DOE's October 2022 consumer FAQ, which also gives rules for older stock. In the North the date of manufacture decides, and in the Southeast and Southwest the date of installation does. DOE's regional map shows which region your state is in, and your installer should know. Read efficiency ratings explained for the full list.

What it costs to run

SEER2 is Btu removed per watt-hour, so the kilowatt-hours for a season are the cooling load in Btu, divided by SEER2, divided by 1,000. Then multiply by your price per kWh.

  1. Pick a load. As a hypothetical, a home needs 18 million Btu of cooling over a summer. A load calculation is how an installer finds your real number.
  2. Divide by SEER2. At 13.4, that is 18,000,000 ÷ 13.4 ÷ 1,000 = 1,343 kWh. At 16 it is 1,125 kWh, and at 18 it is 1,000 kWh.
  3. Apply the price. Texas's 2025 residential average was 15.40¢ per kWh (EIA), so multiply by $0.154.
Summer cooling for a hypothetical 18 million Btu load at 15.40¢ per kWh
SEER2Electricity usedCost
13.41,343 kWhAbout $207
161,125 kWhAbout $173
181,000 kWhAbout $154

The step from 13.4 to 16 is worth about $34 a year in this example. Weigh a gap like that against the price difference on the quote, and against your own load and hours of use. The upgrade savings calculator will take the quoted price and the rebate and show the payback.

Sizing, ducts and the rest of the system

A rating describes the equipment on a test bench. Your result depends on what it is attached to. ENERGY STAR recommends duct sealing alongside home sealing, and says the only way to ensure a new air conditioner performs at its rated efficiency is to replace the heating system at the same time, especially if the furnace is more than 15 years old. Treat that as a question for your installer, not a rule that fits every house. DOE's FAQ makes a related point: a rating applies to a certified combination of outdoor and indoor parts, so ask which combination is being quoted.

  • Size from a load calculation. Do not copy the old unit's tonnage. ENERGY STAR names the Manual J calculation for heat pump sizing, and the same load method applies to cooling.
  • Check the ducts. See ductwork and airflow for what leaks cost and how they are found.
  • Match the pieces. Get the model numbers of the outdoor unit and the indoor coil, and the SEER2 for that pair.

What to ask an installer

  • Did you run a load calculation, and what cooling load did it give?
  • What are the SEER2 and EER2 of the exact outdoor and indoor combination you are quoting?
  • Does the minimum for my region apply, and does this unit meet it?
  • Will you test the ducts, and is sealing in the quote?
  • Does the furnace or air handler need replacing for this air conditioner to work as rated?

Credits and rebates in 2026

The federal Energy Efficient Home Improvement Credit (25C) ended for property placed in service after December 31, 2025, so an air conditioner installed in 2026 earns no federal credit. See what happened to 25C and 25D for the dates and what still counts on a 2025 return. Utilities often run cooling rebates, which commonly need approval before the work, so ask first. DOE says its home energy rebates are available in select states and points to state energy offices for status.

Quick answers

What does SEER2 measure?

DOE defines it as the total heat removed from the conditioned space during the cooling season divided by the total electrical energy used in that season. A higher number means more cooling for each kWh.

Can I compare an old SEER rating with a new SEER2 rating?

Not directly. DOE says SEER2, HSPF2 and EER2 are similar to the older ratings but not directly comparable, so judge each model on its own SEER2.

Do federal minimums differ by region?

Yes. DOE set separate minimums for the North, Southeast and Southwest for equipment installed on or after January 1, 2023. The Southeast and Southwest minimums are higher for smaller units.

Is there a federal tax credit for a new air conditioner?

Not for one placed in service after December 31, 2025. The 25C credit ended on that date. Check utility and state programs before you sign.